Home About Us 24 Hour Support Planned Maintenance Vacancies Contact Us
Blount Shutters - One of the country's largest independant Industrial Door Manufacturers Blount Shutters - Industrial/Retail Doors Manufactured, Installed, Maintained and Repaired


Approved By

Safe Contractor
Achilles
CHAS
The Confederation of Construction Specialists
Eurosafe UK - CDM Competent
Altius Assured Vendor

Company News

December, 2012
Blount Shutters Limited advises client on how to protect against shutter collapses, after near miss, and takes the decision to make the same recommendations to all clients.

November, 2012
Two new Customer Service controllers have joined Blount Shutters Limited to provide support to new accounts.

November, 2012
Blount Shutters Limited has expanded its maintenance division by adding further maintenance teams in continuing to carry out planned maintenance to roller shutters, gates and doors.

October, 2012
Blount Shutters Limited awarded contract to provide reactive and planned maintenance to Tesco's

August, 2012
Engineering teams increased to provide greater coverage across the UK

Fire Shutters

Fire Shutters

Electrically operated Fire Resisting Roller
Shutter - single phase Tube motor operation.

Roller Curtain

75mm deep galvanised cold rolled sections are interlocked together to form the door curtain. The laths are concave in shape and are held together by pressed steel end locks secured by steel rivets. The gauge of the lath is determined by the size of the door and the installation location.

Bottom Rail Section

The bottom rail is normally a galvanised inverted 2.0mm T section.

Side Guides and supporting angles

Guide sections are manufactured from 3mm purpose rolled section, with different depths dependant upon the width of the shutter, and are secured to mild steel angles, pre drilled ready for fixing to the structure.

Roller Shutter Barrel

The mild steel tube encases the single phase tubular motor. The motor head is secured to the shutter end plate, with the outer body rotating to raise and lower the door.

Normal Operation

The Shutter can be used to close off specific areas, and secure products away from the public, typically in kitchen servery areas. A surface wall mounted key operated switch is supplied as standard, mounted to within 500mm of the door opening on the motor side. Flush mounted switches are available at additional cost.

Operation in fire condition

The door will commence closing on receipt of a fire alarm signal generated by the building management system; the operation will be controlled through the Audio Visual warning panel as detailed below.

Audio Visual Warning Closure

An audio & visual warning panel is used to provide a facility for delayed closing, together with an audible indication that the door is to commence its closing cycle.

The fire alarm signal is connected directly into this unit. On activation from the fire alarm the unit starts to flash & sound with the shutter closing after a pre-determined delay (10 - 240 seconds).

A battery back up is also provided as standard, to ensure full protection of the system in the event of a power failure.

Electrical Wiring

A single phase 13 amp power supply is required terminated to a fused spur outlet; in addition, a fire rated cable with a volt free signal in alarm condition terminated to an adaptable is required, all prior to the door installation.

All wiring is carried out by our electrical engineers, to ensure compliance with current regulations.

Mounting of Fused Spur.

To be provided by client, unless agreed otherwise, installed to within 500mm from the motor and control panel position at high level.

Standard Finish

Powder coat finish is available in a wide range of colours and is applied to the complete door on both sides. Powder coat is a more durable and hard wearing finish and is ideally suited to roller shutters.

Click here for powder coated colour options